Two-Family Attached Frame · Built 1901 · 1824 sq ft · 2-story
Inspected 2026-03-29 · Pre-Purchase Home Inspection
Michael German, P.E.
NY License #16000XXXXX
InspectAI Demo
This 1901 two-family attached frame home is in generally fair to good condition for its age. Two critical safety items require immediate attention: an ungrounded subpanel in the basement and evidence of active water intrusion at the rear foundation wall. Six major items including aging roof with flashing deterioration, deteriorating rear deck stairs, cast iron drain pipe corrosion, and inadequate attic ventilation should be addressed within the next 12 months. The property benefits from updated windows (vinyl replacement, ~2015) and a relatively new HVAC system (2019 heat pump). The backyard has significant potential for improvement. Smoke and CO detectors need updating to meet current code. Overall, the property is a solid candidate for purchase with a targeted repair plan.
Overall Condition: Fair to Good
60-amp subpanel in the basement is ungrounded. No equipment grounding conductor connected. This is a safety hazard with risk of electrical shock. Panel appears to be original equipment (likely 1960s upgrade). Panel labeling is incomplete with 4 of 12 breakers unlabeled.
Recommendation: Hire a licensed electrician to install proper grounding and update panel labeling. Estimated cost: $500-800.
Estimated cost: $500-800
Code reference: NEC 250.24, 250.28, 408.4
Visible water staining and efflorescence on the rear foundation wall. Active moisture detected with meter (reading: 28% where threshold for concern is 17%). Appears to originate from grading issues in the backyard directing water toward the foundation.
Recommendation: Address exterior grading to direct water away from foundation. Install or repair perimeter drain. Monitor for structural impact. Estimated cost: $1,500-3,000 for grading + drainage; $3,000-8,000 if interior waterproofing needed.
Estimated cost: $1,500-8,000
Code reference: IRC R401.3, R405.1
Roof appears to be 18-22 years old based on shingle condition. Granule loss visible on south-facing slope. Several tabs lifting. No active leaks detected in attic, but remaining useful life estimated at 3-5 years.
Recommendation: Plan for roof replacement within 3-5 years. Budget $8,000-15,000 for a Brooklyn rowhouse roof. Get quotes from 3 roofers.
Estimated cost: $8,000-15,000 (within 3-5 years)
Step flashing where the roof meets the shared parapet wall is lifting and corroded. Counter-flashing mortar joints are cracked. Sealant has dried and separated in multiple areas. This is a common leak entry point for Brooklyn rowhouses.
Recommendation: Have roofer re-flash the parapet wall junction. Replace step flashing and re-point counter-flashing mortar. Estimated cost: $800-1,500.
Estimated cost: $800-1,500
Code reference: IRC R903.2.1
Metal stairs from upper deck to yard level show significant rust at the base connections. Railing is loose at two attachment points. Stair stringers are corroded. Stairs are functional but approaching end of safe life.
Recommendation: Replace stairs and railing within 12 months. Consider galvanized or powder-coated steel replacement. Estimated cost: $2,000-4,000.
Estimated cost: $2,000-4,000
Main drain stack (cast iron, original 1901) shows heavy external corrosion and scaling. No active leaks detected, but pipe wall thickness is reduced. Cast iron drain pipes of this vintage typically have 75-100 year lifespans and this one is at the end.
Recommendation: Scope the drain with a camera to assess internal condition. Budget for replacement with PVC if scoping reveals significant internal deterioration. Estimated cost: $300-500 for camera scope; $3,000-6,000 for replacement.
Estimated cost: $300-6,000
Backyard grade slopes TOWARD the rear foundation wall rather than away. This is the likely source of the basement water intrusion (Finding F2). Soil is compacted with construction debris with poor drainage.
Recommendation: Re-grade backyard to slope away from foundation at minimum 6 inches over 10 feet. Add garden soil and amend existing soil. This directly addresses the critical water intrusion issue.
Estimated cost: $800-2,000
Attic has only 2 soffit vents and no ridge or gable vents. Calculated net free ventilation area is approximately 1/600 of attic floor area, below the recommended 1/150 ratio for unvented attics with no vapor barrier. Condensation staining visible on underside of roof sheathing.
Recommendation: Add ridge vent or gable vents to achieve proper 1/150 ventilation ratio. This will extend roof life and reduce moisture-related damage. Estimated cost: $400-1,000.
Estimated cost: $400-1,000
Code reference: IRC R806.1
P-trap connection under the kitchen sink shows evidence of a slow drip. Water staining on the base of the cabinet. P-trap appears corroded.
Recommendation: Replace P-trap assembly. Simple DIY fix or ~$150-250 for a plumber.
Estimated cost: $20-250
2nd floor toilet runs for 5-10 seconds every 15-20 minutes. Flapper valve likely worn.
Recommendation: Replace flapper valve. $5-10 part, 10-minute DIY fix.
Estimated cost: $5-10
Paint peeling in several areas on the front facade (wood siding). No rot detected behind peeling areas. Cosmetic issue that will lead to moisture penetration if not addressed.
Recommendation: Scrape, prime, and repaint affected areas. Full exterior paint job recommended within 2 years. Estimated cost: $500-1,000 for touch-up; $3,000-6,000 for full exterior paint.
Estimated cost: $500-6,000
Front gutter is sagging at the center span, causing water to pool rather than flow to the downspout. Debris (leaves and granules) has accumulated in both front and rear gutters. Rear downspout extension is missing, depositing water at the foundation.
Recommendation: Re-hang gutter with new brackets. Clean all gutters and add downspout extensions (min 4 ft from foundation). Estimated cost: $200-500.
Estimated cost: $200-500
Rear soffit shows paint failure and soft spots consistent with early-stage rot at the eaves. Fascia board at the rear is also beginning to deteriorate. Appears moisture-related due to gutter overflow.
Recommendation: Replace affected soffit/fascia sections and repaint. Address gutter issue (F12) first to prevent recurrence. Estimated cost: $300-800.
Estimated cost: $300-800
Tested 3 GFCI outlets in the basement using a plug-in tester. Two of three did not trip when tested. These outlets are near the laundry area and utility sink where water exposure is likely.
Recommendation: Replace non-functioning GFCI outlets. Estimated cost: $50-150 (DIY) or $150-300 (electrician).
Estimated cost: $50-300
Code reference: NEC 210.8(A)(5)
Kitchen smoke detector is expired (manufactured 2014, 10-year lifespan). No CO detector found on garden level despite gas range. 2nd floor has working smoke detector but no CO detector. NYC requires CO detectors within 15 ft of any bedroom.
Recommendation: Install new combination smoke/CO detectors on every level. Replace expired units. Estimated cost: $80-200 for 4 combination units.
Estimated cost: $80-200
Code reference: NYC Admin Code 27-2046.1, NFPA 720
50-gallon electric water heater (Bradford White, 2018) is in serviceable condition. Temperature set to 125F (slightly above recommended 120F). Anode rod has not been replaced (manufacturer recommends every 3-5 years). No expansion tank installed. Unit has approximately 4-6 years of remaining useful life.
Recommendation: Lower temperature to 120F, replace anode rod to extend tank life, and consider adding an expansion tank. Estimated cost: $150-250 for anode rod; $100-200 for expansion tank.
Estimated cost: $150-450
Static water pressure measured at 85 PSI at the basement hose bib. Recommended range is 40-80 PSI. High pressure can stress pipe joints, cause running toilets, and reduce appliance lifespan.
Recommendation: Install a pressure reducing valve (PRV) at the main water entry. Estimated cost: $200-400.
Estimated cost: $200-400
Code reference: IRC P2903.3.1
Mitsubishi mini-split filter in the kitchen head unit is visibly dirty with restricted airflow. Filter should be cleaned monthly during heating/cooling season. Condensate drain line is clear. Refrigerant lines are properly insulated at the exterior.
Recommendation: Clean or replace filter immediately and set a monthly reminder. Filters are washable on this model.
Estimated cost: $0 (DIY cleaning)
Tested the garage door auto-reverse by placing a 2x4 on the floor. Door did not reverse on contact. Photo-eye sensors are present but misaligned. Door opener is a Chamberlain unit, approximately 2012 vintage.
Recommendation: Realign photo-eye sensors and adjust auto-reverse sensitivity. If adjustment does not resolve, replace opener. Estimated cost: $0 for adjustment; $250-500 for new opener.
Estimated cost: $0-500
Code reference: UL 325
The garage shares a wall with the garden-level living space. Required fire-rated separation (5/8-inch Type X drywall) is present but has an unsealed penetration around a dryer vent duct and a gap at the ceiling junction approximately 3 inches wide.
Recommendation: Seal the drywall gap and duct penetration with fire-rated caulk or additional drywall. Estimated cost: $50-150.
Estimated cost: $50-150
Code reference: IRC R302.6
One double-pane vinyl replacement window in the master bedroom shows condensation between the panes, indicating seal failure. Window still operates normally and has no air infiltration. This is a cosmetic issue that reduces insulating value by approximately 10-15%.
Recommendation: Replace the insulated glass unit (IGU) or the full sash. Estimated cost: $200-400 per IGU; $300-600 per sash.
Estimated cost: $200-600
Double-hung window in the 2nd floor bathroom is painted shut at the bottom sash. Top sash moves freely. Window is the only means of ventilation in this bathroom (no exhaust fan). Emergency egress may be compromised.
Recommendation: Free painted sash by scoring paint line and lubricating tracks. Estimated cost: $0 (DIY) or $100-200 for a handyman.
Estimated cost: $0-200
Cast iron and marble fireplace in the living room appears to be original (1901). Good cosmetic condition. Flue not tested (outside scope). Decorative use only unless flue is inspected and cleaned.
Recommendation: Have chimney sweep inspect and clean flue before any use. Informational only, not a defect.
Estimated cost: $150-300 for chimney inspection
Fiberglass batt insulation measured at R-19 (approximately 6 inches). Current NYC Energy Code requires R-49 for attic insulation. No vapor barrier present. Insulation is in fair condition with some displacement and compression.
Recommendation: Consider adding blown-in cellulose or additional batts to achieve R-49. Energy savings would be approximately $200-400/year. Estimated cost: $1,500-3,000 for blown-in insulation.
Estimated cost: $1,500-3,000 (energy upgrade)
Code reference: IECC C402.1.3, NYC Energy Code
Found scattered rodent droppings (likely mouse) along the east wall of the attic near the soffit vents. Droppings appear old and desiccated (not recent). No nesting material, gnaw marks on wiring, or other signs of active infestation observed.
Recommendation: Seal soffit vent gaps with hardware cloth (1/4-inch mesh). Set monitoring traps. No immediate treatment needed. Estimated cost: $50-100 for exclusion materials.
Estimated cost: $50-100
Front stoop is original brownstone in good condition for its age. Minor surface spalling on the top step and some biological growth on the north side. Wrought iron railing is secure. No structural concerns.
Recommendation: Clean biological growth with appropriate masonry cleaner. Monitor spalling; patching available if cosmetic appearance is a concern.
Estimated cost: $0-200 (cosmetic only)
Original heart pine hardwood flooring throughout the garden level is in good condition. Some minor squeaking in the hallway. Finish is worn in high-traffic areas but wood is solid with no soft spots or water damage.
Recommendation: Refinishing recommended within the next 3-5 years to preserve the wood. Estimated cost: $3-5/sq ft ($5,500-9,000 for full garden level).
Estimated cost: $5,500-9,000 (optional refinishing)
Cost estimates are approximate ranges based on typical Brooklyn contractor pricing as of 2026. Actual costs may vary. Get multiple quotes for any significant repair.
| electric | ConEdison, 200A service, average $180/month (owner-reported) |
| gas | National Grid, gas range and potential gas dryer hookup |
| water | NYC DEP municipal water, metered |
| sewer | NYC DEP combined sewer system |
| internet | Verizon FiOS available, Spectrum cable available |
| type | Vinyl double-pane replacement windows |
| approximate age | ~11 years (installed ~2015) |
| condition | Good overall; 1 seal failure in master bedroom |
| count | 14 windows total |
| original windows | None remaining (all replaced) |
LiDAR scan data from the inspection creates an interactive 3D walkthrough. Click on any room to see findings, photos, and measurements in context.
Captured with iPhone LiDAR + Apple RoomPlan
This report identified $3,200-8,000 in estimated repairs. Get competitive quotes from top-rated local contractors.
Report generated by InspectAI · InspectAI Demo · NY License #16000XXXXX
This report is the professional opinion of the inspector and is not a guarantee or warranty. Refer to the inspection agreement for terms and limitations.